EasyManua.ls Logo

Delta MH300 Series - Page 270

Delta MH300 Series
1030 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 11 Summary of Parameter Settings
MH300
11-11
Pr. Parameter Name Setting Range Default
01-20 JOG acceleration time
Pr.01-45 = 0: 0.00600.00 sec.
Pr.01-45 = 1: 0.006000.00 sec.
10.00
01-21 JOG deceleration time
Pr.01-45 = 0: 0.00600.00 sec.
Pr.01-45 = 1: 0.006000.00 sec.
10.00
01-22 JOG frequency 0.00599.00 Hz 6.00
01-23
First / Fourth acceleration
/ deceleration exchange
frequency
0.00599.00 Hz 0.00
01-24
S-curve acceleration
begin time 1
Pr.01-45 = 0: 0.0025.00 sec.
Pr.01-45 = 1: 0.00250.00 sec.
0.20
01-25
S-curve acceleration
arrival time 2
Pr.01-45 = 0: 0.0025.00 sec.
Pr.01-45 = 1: 0.00250.00 sec.
0.20
01-26
S-curve deceleration
begin time 1
Pr.01-45 = 0: 0.0025.00 sec.
Pr.01-45 = 1: 0.00250.00 sec.
0.20
01-27
S-curve deceleration
arrival time 2
Pr.01-45 = 0: 0.0025.00 sec.
Pr.01-45 = 1: 0.00250.00 sec.
0.20
01-28
Skip frequency 1
(upper limit)
0.00599.00 Hz 0.00
01-29
Skip frequency 1
(lower limit)
0.00599.00 Hz 0.00
01-30
Skip frequency 2
(upper limit)
0.00599.00 Hz 0.00
01-31
Skip frequency 2
(lower limit)
0.00599.00 Hz 0.00
01-32
Skip frequency 3
(upper limit)
0.00599.00 Hz 0.00
01-33
Skip frequency 3
(lower limit)
0.00599.00 Hz 0.00
01-34 Zero-speed mode
0: Output waiting
1: Zero-speed operation
2: Minimum frequency (refer to Pr.01-07 and Pr.01-41)
0
01-35 Motor 2 output frequency 0.00599.00 Hz
60.00 /
50.00
01-36 Motor 2 Output voltage
115 / 230 V models: 0.0255.0 V
460 V models: 0.0510.0 V
220.0
440.0
01-37
Motor 2 Mid-point
frequency 1
0.00599.00 Hz 3.00
01-38
Motor 2 mid-point voltage
1
115 / 230 V models: 0.0240.0 V
460 V models: 0.0480.0 V
11.0
22.0

Table of Contents