Chapter 11 Summary of Parameter Settings
MH300
11-13
Pr. Parameter Name Setting Range Default
01-59
Motor 3 mid-point voltage
2
115 / 230 V models: 0.0240.0 V
460 V models: 0.0480.0 V
5.0
10.0
01-60
Motor 3 minimum output
frequency
0.00599.00 Hz 0.50
01-61
Motor 3 minimum output
voltage
115 / 230 V models: 0.0240.0 V
460 V models: 0.0480.0 V
1.0
2.0
01-62
Motor 4 maximum
operation frequency
0.00599.00 Hz
60.00 /
50.00
01-63 Motor 4 output frequency 0.00599.00 Hz
60.00 /
50.00
01-64 Motor 4 output voltage
115 / 230 V models: 0.0255.0 V
460 V models: 0.0510.0 V
220.0
440.0
01-65
Motor 4 mid-point
frequency 1
0.00599.00 Hz 3.00
01-66
Motor 4 mid-point voltage
1
115 / 230 V models: 0.0240.0 V
460 V models: 0.0480.0 V
11.0
22.0
01-67
Motor 4 mid-point
frequency 2
0.00599.00 Hz 1.50
01-68
Motor 4 mid-point voltage
2
115 / 230 V models: 0.0240.0 V
460 V models: 0.0480.0 V
5.0
10.0
01-69
Motor 4 minimum output
frequency
0.00599.00 Hz 0.50
01-70
Motor 4 minimum output
voltage
115 / 230V models: 0.0240.0 V
460 V models: 0.0480.0 V
1.0
2.0
01-72
V/F separated mode,
Voltage Input Percentage
0.00100.00 50.00
01-73
V/F separated mode,
Voltage Input Source
Selection
0: Digital Keypad
1: RS-485 communication
2: Reserved
3: AVI Analog input
4: ACI Analog input
5: Reserved
6: CANopen communicaton
7: Communication Card
0
01-74
V/F separated mode,
Voltage increasing time
1.00600.00 0.00
01-75
V/F separated mode,
Voltage decreasing time
1.00600.00 0.00