Chapter 11 Summary of Parameter Settings
MH300
Pr. Parameter Name Setting Range Default
02-52
Display the external
multi-function input
terminals used by PLC
Monitor the status of PLC input terminals Read only
02-53
Display the external
multi-function output
terminals used by PLC
Monitor the status of PLC output terminals Read only
02-54
Display the Frequency
command executed by
external terminal
0.00–599.00 Hz (Read only) Read only
02-58
Multi-function output
terminal (function 42):
brake frequency check
point
0.00–599.00 Hz 0.00
02-70 IO card type
1: EMC-BPS01 (backup power supply)
10: EMM-D33A
11: EMM-A22A
12: EMM-R2CA
13: EMM-R3AA
Read only
02-74
Internal / external
multi-function input
terminal selection
0000–FFFFh
0000h
02-75
Internal multi-function
output terminal selection
0000–FFFFh
0000h
02-81
EF activates when the
terminal count value
reached
0: Terminal count value reached, no EF displays
(continues operating)
1: Terminal count value reached, EF is active
0
02-82
Initial frequency command
(F) mode after stop
0: Use current frequency command
1: Use zero frequency command
2: Refer to Pr.02-83 to setup
0
02-83
Initial frequency
command
(F) setting after stop
0.00–599.0 Hz 60.00