Chapter 11 Summary of Parameter Settings
MH300
Pr. Parameter Name Setting Range Default
bit9: Speed unit selection
bit10: Speed unit selection
bit11: Speed unit multiple
11-62
Encoder at Load Side ppr
Number (High Byte)
0–65535 0
11-63
Encoder at Load Side ppr
Number (Low Byte)
0–65535 2400
11-64
Single-Point Positioning
Rising Speed
0.10–depending on the maximum setting value calculated
by setting value of Pr.11-43 and Pr.11-45
10.00
11-68
Homing Method
0000h–0128h 0008h
11-69
Homing Control Time Out
0.0–6000.0 sec. 60.0
11-70
Homing Control 1st Step
Speed
0.00–599.00 Hz 8.00
11-71
Homing Control 2nd Step
Speed
0.00–599.00 Hz 2.00
11-72
Homing Control
Acceleration /
Deceleration Time
(0–Homing Control 1
st
Step Speed)
0.00–600.00 sec. 10.00
11-73
Homing Control Offset
(Revolution)
-30000–30000 revolutions 0
11-74
Homing Control Offset
(Pulse)
Refer to Pr.10-01 setting 0
11-75
Position Record
(Revolution)
-30000–30000 revolutions 0
11-76
Position Record (Pulse)
Refer to Pr.10-01 setting 0
11-78
HALT Revived Selection
0: Stopped
1: Continue according to the previous position command
0