Chapter 12 Description of Parameter Settings
MH300
12.1-12-2
Example:
A summary of the parametersTension closed-loop, speed mode
Tractor
(Drive 1)
Pr.
Parameter name
Setting
Note
00-20
Master frequency command source (AUTO,
REMOTE)
2
Inputs from external analog
(refer to Pr.03-00)
00-21
Operation command source (AUTO, REMOTE)
1
Operates by using external terminals
02-16
Multi-function output 2 (MO1)
1
Indication during RUN
03-20
AFM multi-function output
0
Output frequency (Hz)
Winder
machine
(Drive 2)
Pr.
Parameter name
Setting
Note
00-21
Operation command source (AUTO, REMOTE)
1
Operates by using external terminals
03-00
AVI analog input selection
15
Linear speed
03-01
ACI analog input selection
14
Tension PID feedback signal
12-00
Tension control selection
1
Closed-loop tension, speed mode
12-02
Mechanical gear A at load side
100
Depends on working condition
12-03
Mechanical gear B at motor side
100
Depends on working condition
12-04
PID target source
0
Set by parameter (Pr.12-05)
12-05
PID target value
50
Depends on working condition
12-06
PID feedback source selection
0
Analog input
12-19
Linear speed input command source
1
Analog input
12-27
Reel diameter source
0
Calculated via linear speed
Setting value 2: Closed-loop linear speed, speed mode

Table of Contents