Chapter 12 Description of Parameter Settings
MH300
Tension Taper Curve Selection
Default: 0
Settings 0: No taper
1: Curve taper
2: Linear taper
3: Multi-step curve taper
4: Multi-step linear taper
When Pr.12-01 = 1, this function is invalid.
In some situations, users request the tension decreases along with the increasing reel diameter
to ensure that the material is smoothly rewinded. To meet the goal, you can set the tension taper
related parameters.
When Pr.12-65 = 1, the curve is generated by Pr.12-67, and the curve can be fine-tuning by
Pr.12-68.
When Pr.12-65 = 2, the linear taper is generated by Pr.12-67.
When Pr.12-65 = 3, determines the taper of multi-curves by Pr.12-67, Pr.12-71 and Pr.12-72; and
determines the turning points by Pr.12-69 and Pr.12-70.