Chapter 13 Warning Codes|MH300
13-16
ID No.
Display Warning Name Description
17
Over speed warning
(oSPd)
Over speed warning
Action and Reset
Action level The encoder feedback speed > Pr.10-10
Action time Pr.10-11
Warning setting parameter
Pr.10-12=0
0: Warn and keep operation
Reset method Warningautomatically clears when the drive stops
Reset condition Warningautomatically clears when the drive stops
Record N/A
Cause Corrective Actions
Improper setting for Pr.10-25
FOC bandwidth of speed
observer
Decrease setting value for Pr.10-25.
Improper bandwidth setting for
ASR speed controller
Increase the bandwidth setting for ASR speed controller.
Incorrect motor parameter
setting
Reset motor parameter and run parameter tuning.
Malfunction caused by
interference
Verify wiring of the control
circuit, and wiring/grounding of the main circuit
to prevent interference.

Table of Contents