Chapter 13 Warning Codes|MH300
13-73
ID No.
Display Warning Name Description
93
Copy PLC: version
error (CPLv)
Copy PLC version error.
When a non-MS300 built-in PLC is copied to
the
MH300 drive, the CPLv warning occurs.
Action and Reset
Action level Software detection
Action time Immediately act
Warning setting parameter N/A
Reset method Manual reset
Reset condition Directly reset
Record N/A
Cause Corrective Actions
A non-MH300 PLC program is
copied to MH300
Check if the copied PLC program is for MH300.
Use the correct MS300 PLC program.