Chapter 13 Warning Codes|MH300
13-74
ID No.
Display Warning Name Description
94
Copy PLC
: size error
(CPLS)
Copy PLC capacity error
Action and Reset
Action level Software detection
Action time Immediately act
Warning setting parameter N/A
Reset method Manual reset
Reset condition Directly reset
Record N/A
Cause Corrective Actions
The PLC program copied to
MH300 exceeds the allowable
capacity
Check if the copied PLC program is for MH300
Use the correct capacity for the MH300 PLC program