Components description | 8
DOCMA0000006‐UK ﴾ENG﴿ ‐ Samson FPT 3A 109
8.3.1 Pressure gauge
Thepressuregauge(fig.1507421)
is used to control the servo brake
pressure. In case of anomalies and
faults,thepressuremaydrop.
150742-1
DANGER
The pressure should not drop below 18 bar (1.8 MPa – 260 psi).
In the case of low pressure (below 18 bar) stop the machine and contact an authorized Dieci dealer to
eliminate the defect.
DANGER
It is absolutely forbidden to operate with servo brake accumulator pressure less than 18 bar (1.8 MPa
260 psi).
8.3.2 Braking circuit errors list
NOTICE
In case the machine is in error, contact a Dieci service center to solve the problem, indicating the error
code reported.
For more information about the errors display, refer to the "Central instrument panel" chapter.
Icon Example Description
000000000 Parkingbrakeserrorsorbrakesfailure
Code Description
100 Servicebrakeslowoillevelreporting
101 Parchingbrakesystemfailure
102 Parkingbrakeaccumulatorlowpressure