Problems diagnostics | 14
DOCMA0000006‐UK ﴾ENG﴿ ‐ Samson FPT 3A 259
14 Problems diagnostics
WARNING
The interventions for the elimination of faults can only be carried out by trained personnel.
Donotworkonfailuresifthe"Safetyregulations","SafeWorkingProcedures"and"MAINTENANCE"havenot
beenreadandunderstoodbefore.
This symbol indicates that the trouble experienced may NOT be resolved without the
interventionofaDIECIServiceauthorizedworkshop
14.1 Engine
TROUBLE CAUSE SOLUTION
Itdoesnotsetinmotion Directionoftravelleverengaged Placetheleverinneutral
Operator not properly seated in the
driver'sseat
Sitproperlyincab
Nofuel Fillthetank
Batterycutoffswitchdisconnected Connectthebatterycutoffswitch
LowBattery Rechargethebatteryorreplaceit
Fusefailure Replacethefuse
Other Consult the Use and Maintenance
manualoftheengine
14.2 Hydraulic transmission system
TROUBLE CAUSE SOLUTION
The vehicle does not go in
anydirection
Insufficienthydraulicoillevel Checkthehydraulicoillevel
Electronic accelerator entered (if
installed)
Disconnecttheelectronicaccelerator
The sensor builtin the seat does not
reportthepresenceoftheoperator
Sitproperlyatthedriver'sseat
The movement selection lever is not
engaged
Engagethelevertothedesiredposition
Theoutriggersarelowered(ifinstalled) Raisealloutriggersfullyup
Rearaxlelocked(ifinstalled) Releasetheaxle
Parkingbrakeinoperation Disengagethebrake
Electricalcircuitfailure Repairthecircuit
Hydrostatictransmissionfailure Repairorreplacethetransmission
The ByPass valve for the machine
towingwasclosed
OpentheByPassvalve