EasyManua.ls Logo

Dieci SAMSON AGRI MAX - Page 124

Dieci SAMSON AGRI MAX
358 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 | Components description
124 DOCMA0000006‐UK ﴾ENG﴿ ‐ Samson FPT 3A
CODE COMPONENT ALARM
090.E4 Powersupply+5Vdc Output voltage lower than the lower limit of operation of the
Joystickandoftherotationsensor(ControlUnitMalfunction)
091.E4 Outputvoltagehigher thantheupperlimit ofoperationofthe
Joystickandoftherotationsensor(ControlUnitMalfunction)
101.E4 SWITCHJOYSTICK ENGINESTARTwithdeadmanswitchnotreleasedorbroken
110.E4 RollerJOYSTICK Redundancycontroloutoftolerance
111.E4 Atleastonesignaloutofrange
114.E4 Redundancycontroloutoftolerance
115.E4 Atleastonesignaloutofrange
118.E4 Redundancycontroloutoftolerance
119.E4 Atleastonesignaloutofrange
140.E4 LowIdleUpsolenoidvalve Output not commanded but a too high current consumption
hasbeendetected
141.E4 Output commanded but a too low current consumption has
beendetected
142.E4 Output commanded but a too high current consumption or a
shortcircuithavebeendetected
145.E4 Buttonpressedduringtheenginestarting
150.E4 Solenoidvalve
Distributor
Not commanded but a current consumption exceeding the
threshold has been detected
(ControlUnitMalfunction)
151.E4 Commanded but the control unit does not detect a current
consumption exceeding the threshold (Control Unit or
DistributorMalfunction)
152.E4 Output commanded but the control unit detects a high
consumption
(ControlUnitorDistributorMalfunction)
160.E4 Solenoidvalve
Servocontrol
Not commanded but a current consumption exceeding the
threshold has been detected
(ControlUnitMalfunction)
161.E4 Commanded but the control unit does not detect a current
consumption exceeding the threshold (Control Unit or
DistributorMalfunction)
162.E4 Output commanded but the control unit detects a high
consumption
(ControlUnitorDistributorMalfunction)
170.E4 ForwardCommand Not commanded but a current consumption exceeding the
threshold has been detected
(ControlUnitMalfunction)
172.E4 Output commanded but the control unit detects a high
consumption
(ControlUnitorDistributorMalfunction)
180.E4 ReserveCommand Not commanded but a current consumption exceeding the
threshold has been detected
(ControlUnitMalfunction)
182.E4 Output commanded but the control unit detects a high
consumption
(ControlUnitorDistributorMalfunction)

Table of Contents