Marking lamps
Service Instructions 745-35-10 S/745-35-10 A - 02.0 - 04/2017 111
7.2 Aligning the laser modules (745-35-10 A)
Fig. 94: Aligning the laser modules (1)
WARNING
Risk of injury from laser light!
Risk of sustaining eye damage and going blind.
NEVER look into the laser light source.
(1) - Needles
(2) - Cutting line
(3) - Marking of the front positioning point
(varies with the setting of the sewing
length)
(4) - Middle of pocket opening (varies with
the setting of the sewing length)
(5) - Marking of the rear positioning point
(6) - Edge of the sliding plate (measuring
line)
Sewing length (mm) Spacing A (mm)
200 91
180 111
240 123
220 143
①②