Maintenance
306 Service Instructions 745-35-10 S/745-35-10 A - 02.0 - 04/2017
Proper setting
The necessary oil quantity has been set at the factory using screws (1)
and (2). It should only be increased or reduced in exceptional cases.
To lubricate the hook:
1. Adjust the oil quantity.
• Less oil: Turn screws (1) and (2) clockwise
• More oil: Turn screws (1) and (2) counterclockwise
17.3 Servicing the pneumatic system
17.3.1 Setting the operating pressure
Proper setting
Refer to the Technical data ( p. 39) chapter for the permissible operating
pressure. The operating pressure cannot deviate by more than ± 0.5 bar.
Check the operating pressure on a daily basis.
Abb. 268: Setting the operating pressure
NOTICE
Property damage from incorrect setting!
Incorrect operating pressure can result in damage to the machine.
Ensure that the machine is only used when the operating pressure
is set correctly.
(1) - Pressure controller (2) - Pressure gage