Folder
138 Service Instructions 745-35-10 S/745-35-10 A - 02.0 - 04/2017
3. Loosen the nuts (4) and threaded pins (5) until the dimension x is
adjusted along the entire length of the sole.
4. Tighten the nuts (4).
5. Tighten the screws (6).
12.3 Setting the stroke movement of the folder
Fig. 119: Setting the stroke movement of the folder (1)
Proper setting
When the folder is lowered
The plate cam (2) is set such that the folder is first raised vertically by
approx. 6 mm when swiveling up before being swung out of the sewing area.
When the folder is raised
When the folder is raised, there must be some clearance between the
guide roller (1) and the highest point of the guide groove (3).
WARNING
Risk of injury from moving parts!
Crushing possible.
Set the stroke movement of the folder only with the
sewing unit switched off.
(1) - Guide roller (2) - Plate cam