Loading...
Setting the folding station plate
Service Instructions 745-35-10 S/745-35-10 A - 02.0 - 04/2017 127
9 Setting the folding station plate
Fig. 109: Setting the folding station plate (1)
Proper setting
The distance between the middle of the needle and the outer side of the
folding station plate (1) must be 87 mm.
To set the folding station plate:
1. Use a strip or an angle to extend the folding station plate (1) to the
sliding plate surface.
2. Check the distance to the needle.
WARNING
Risk of injury from moving parts!
Crushing possible.
Set the folding station plate only when the sewing
unit is switched off.
(1) - Folding station plate
87 mm