Machine head
Service Instructions 745-35-10 S/745-35-10 A - 02.0 - 04/2017 31
3.8.2 Removing a needle bar from the needle bar linkage
Fig. 19: Removing a needle bar from the needle bar linkage (1)
To remove a needle bar from the needle bar linkage:
1. Loosen the clamping screw (1).
2. Pull out the bearing bolt (3).
3. Pull the support plate (2) off the needle bar linkage.
(1) - Clamping screw
(2) - Support plate
(3) - Bearing bolt