Light barriers
122 Service Instructions 745-35-10 S/745-35-10 A - 02.0 - 04/2017
17. Insert the template (2) (slanted pocket) such that line (6) points to the
left needle and is parallel to the right transport clamp.
18. Press the button.
The flap clamp closes.
19. Fix the erect template (2) on the left in place on the clamp using a strip
of adhesive tape (5).
20. Press the button.
The template (2) is scanned.
The display shows the scanned parameters. The scanned parame-
ters are automatically adopted by the control.
Fig. 104: Setting the light barriers for automatic slant detection (3)
21. Press the button.
The flap clamp opens.
22. Remove the template (2).
23. Press the button.
The settings are stored, and the display switches to Machine test.
24. Slide the transport clamps to the rear by hand.
25. Swing in the folding station.
26. Switch off the sewing unit.