Machine head
54 Service Instructions 745-35-10 S/745-35-10 A - 02.0 - 04/2017
Fig. 42: Setting the distance between hook tips and needles (3)
9. Loosen the screw (9).
10. Return the needle guard (14) by turning the eccentric bolt (8).
11. Remove the needle from the needle holder.
12. Insert the setting peg (3) into the needle holder as far as it will go.
13. Swivel up the machine head.
14. Loosen screws (13) and (10).
15. Shift the hook support (11) laterally.
 The hook tip should slightly touch, but not displace, the measuring 
surface (12) of the setting peg (3).
16. Tighten the screws (13).
17. Tighten the screws (10).
18. Assemble bobbin case bottom parts and hook cover.
19. Screw on the throat plate.
(3) - Setting peg
(8) - Eccentric bolt
(9) - Screw
(10) - Screw
(11) - Hook support
(12) - Measuring surface
(13) - Screws