EasyManuals Logo

Edwards GXS Series User Manual

Edwards GXS Series
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #125 background imageLoading...
Page #125 background image
Table 28
PDT displays
Pump state
Local control
LED
PDT display Operator Pump response
Press Start buon PDT displays:
Stopped On START MENU
Start Pump
Press ENTER to conrm Pump starts
Running On Pump Running
Press CANCEL
Press CANCEL No change
(running)
Stopped or Running O No PDT Control
Press CANCEL
Press CANCEL No change
Press Stop buon PDT displays:
Stopped On PUMP Stopped
Press CANCEL
Press CANCEL No change
(stopped)
Running On STOP MENU
Auto Shutdown
If Fast Shutdown is
required, press the
down arrow. Press
ENTER to conrm
Pump stops
Stopped or Running O No PDT Control
Press CANCEL
Press CANCEL No change
9.3 Event/warning/alarm display and acknowledgement
Each new event/warning/alarm is displayed when it occurs, overwring any text already
present unless another unacknowledged event/warning/alarm is currently being
displayed. The corresponding warning/alarm LED ashes to indicate a new event/
warning/alarm.
Pressing ENTER acknowledges the event/warning/alarm currently displayed and the
warning/alarm LED stops ashing. If available, the display will show the suggested
acon, press ENTER again to clear.
If there is another new event/warning or alarm the warning/alarm LED will connue to
ash and this is then displayed, otherwise the display will revert to the original text from
before the alarms/warnings/events occurred.
If there are warnings/alarms sll present, but they are all acknowledged, then the
corresponding LED remains connuously illuminated. The text indicang acknowledged
warning/alarm condions sll present may be viewed in the Status menu, refer to status
menu contents in Status menu on page 122. Some alarms such as 1.01 STOP ACTIVATED
remain present unl the pump is manually started from the PDT or front panel controls.
Once all warning/alarm condions have gone away, then the corresponding LED is
exnguished.
To avoid a buildup of out of date warnings, they are automacally acknowledged aer
36 hours.
9.4 Menus
There are three menu buons NORMAL, STATUS and SETUP described below.
Page 121
M58800880_H - Pump display terminal

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards GXS Series and is the answer not in the manual?

Edwards GXS Series Specifications

General IconGeneral
BrandEdwards
ModelGXS Series
CategoryWater Pump
LanguageEnglish

Related product manuals