9.9.3 Automacally iniang a clean cycle when the pump goes o-process
The dry pump can be congured to automacally start the dry pump clean cycle when it
goes oprocess. This is useful if the pump requires regular cleaning on a parcularly
dirty process. This mode is enabled by seng enable in the Start in the Green mode
menu item.
9.9.4 Turn the inlet purge on during the clean cycle
To increase the gas ow through the dry pump during a clean cycle, it is possible to
congure the inlet purge gas valve to be open during the clean cycle. This mode is
enabled by seng enable in the Inlet purge menu item.
9.9.5 Have inlet purge cycle aer clean cycle
For some processes it is desirable to ensure that the pump is both fully dry and
internally warm aer a clean cycle has been completed. The pump can be congured to
have an oponal inlet purge cycle where the pump runs at full speed. To enable this
opon, use the Purge me menu item and set the purge me to a value greater than
zero.
9.9.6 Allow on process
Allows a DP Clean to start while the pump is onprocess.
9.9.7 Auto on shut down
When enabled, a DP clean cycle occurs aer every pump auto shutdown.
9.10 How to control the pump speed
By default, both the dry pump and booster runs at full speed while the pump is
onprocess. For some applicaons, it is advantageous to adjust the speed of the pump
while it is onprocess so the system has the capability to run both the dry pump and
booster at dierent speeds.
The speeds of the dry pump and booster can be controlled using a number of dierent
methods as shown in Table: Speed control sources.
Table 51
Speed control sources
Speed control sources:
Normal speed (default)
External voltage 0-10 V input*
SIM protocol over one of the serial RS232 interfaces
SIM protocol over the Ethernet interface
As a second speed controlled from the PDT*
As a second speed controlled from the MCM MicroTIM*
Page 144
M58800880_H - Pump display terminal

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards GXS Series and is the answer not in the manual?

Edwards GXS Series Specifications

General IconGeneral
BrandEdwards
ModelGXS Series
CategoryWater Pump
LanguageEnglish

Related product manuals