Table 38
DP clean opons menu
Opon Text on PDT line 2
Opons on PDT line 2 aer
pressing Enter
Set clean speed Set DP Speed... Range 20 to 110 Hz*
Clean me Clean Time... Range 10 minutes to 60 minutes*
Automacally start on
entering Green Mode
Start in Green Mode ... Enable/Disable
Inlet purge open during
clean cycle
Inlet Purge... Enable/Disable
Inlet purge me aer
clean cycle
Purge Time Range 0 minutes to 60 minutes*
Allow DP clean when
pump is on process
Allow on Process Enable/Disable
Automacally run DP
clean during shutdown
Auto On Shutdown Enable/Disable
Allow DP clean when
pump is on process
Allow on Process Enable/Disable
Automacally run DP
clean during shutdown
Auto On Shutdown Enable/Disable
* Scroll through the opons by pressing the UP/DOWN keys. Press ENTER to accept the
new seng. Press CANCEL to exit back into the DP clean menu.
Press the UP/DOWN keys to select enable/disable and press ENTER to accept or CANCEL
to exit back to the DP clean menu.
9.4.11 Warn on-process menu
Press the UP/DOWN keys to select enable/disable and press ENTER to accept or CANCEL
to exit back to the Set sequences menu.
9.4.12 On-process ramp menu
Scroll by pressing the UP/DOWN keys. Press ENTER to open a sub menu or CANCEL to
exit back to the Set sequences menu.
Table 39
On-process ramp opons menu
Opon
Text on PDT line
2
Opons
on PDT line 2 aer pressing
Enter
Time between speed step
changes
Ramp Time... Range 0
‑ 3600 seconds in 60 second
steps
Size of speed step changes Ramp Step... Range 5 to 110 Hz in Hz steps
Scroll through the opons by pressing the UP/DOWN keys. Press ENTER to accept the
new seng. Press CANCEL to exit back into the On‑process ramp menu.
Page 127