EasyManua.ls Logo

Edwards GXS Series

Edwards GXS Series
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. Technical data
2.1 General technical data
Table 1
General technical data
Item
Descripon Rang Units
Operang condions
Intended use Indoor
Ambient temperature range:
Operang
Storage
5 to 40
-45 to 55
°C
°C
Maximum relave humidity:
80% for temperatures up to 31 °C
decreasing linearly to 50% relave
humidity at 40 °C
Maximum operang altude 2000 m
Polluon degree 2 (IEC 61010)
Materials in contact
with the process gas
Pump, sha and rotors Cast SG iron
Seals PTFE and uoroelastomer
Gas system
Stainless steel, aluminium, brass,
PTFE and uoroelastomer
Materials in contact
with the process gas
Pump, sha and rotors Cast SG iron
Seals PTFE and uoroelastomer
Gas system
Stainless steel, aluminium, brass,
PTFE and uoroelastomer
Degree of protecon
Hazardous electrical sub
system
IP21D (IEC60529)
Lubricaon Oil type
PFPE Drynert 25/6 (recommended)
Fomblin
®
25/6 (alternave)
Krytox
®
1525 (alternave)
Page 15
M58800880_H - Technical data

Table of Contents

Related product manuals