2. Technical data
2.1 General technical data
Table 1
General technical data
Item
Descripon Rang Units
Operang condions
Intended use Indoor
Ambient temperature range:
Operang
Storage
5 to 40
-45 to 55
°C
°C
Maximum relave humidity:
80% for temperatures up to 31 °C
decreasing linearly to 50% relave
humidity at 40 °C
Maximum operang altude 2000 m
Polluon degree 2 (IEC 61010)
Materials in contact
with the process gas
Pump, sha and rotors Cast SG iron
Seals PTFE and uoroelastomer
Gas system
Stainless steel, aluminium, brass,
PTFE and uoroelastomer
Materials in contact
with the process gas
Pump, sha and rotors Cast SG iron
Seals PTFE and uoroelastomer
Gas system
Stainless steel, aluminium, brass,
PTFE and uoroelastomer
Degree of protecon
Hazardous electrical sub
system
IP21D (IEC60529)
Lubricaon Oil type
PFPE Drynert 25/6 (recommended)
Fomblin
®
25/6 (alternave)
Krytox
®
1525 (alternave)
Page 15
M58800880_H - Technical data

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards GXS Series and is the answer not in the manual?

Edwards GXS Series Specifications

General IconGeneral
BrandEdwards
ModelGXS Series
CategoryWater Pump
LanguageEnglish

Related product manuals