Figure 64 Dry pump clean PDT menu conguraon items
9.9.1 Changing the dry pump speed during the clean operaon
Use the Set DP speed menu item to change the dry pump speed during the clean cycle.
It is not recommended to increase the pump speed if solvent is used. If the dry pump
clean is just using air then seng the speed to 110 Hz would increase the eciency of
the cleaning cycle.
9.9.2 Changing the clean cycle me
The me period for the dry pump clean cycle can be changed using the DP clean me
menu item.
Page 143
M58800880_H - Pump display terminal