Table 36
Booster pump start opons menu
Opon Text on PDT line 2
Opons on PDT line 2 aer pressing
Enter
Booster start mode BP Start Mode Select from:
Manual
Time Delay
Booster controller if in Time
Delay Mode
BP delay aer.. Select from:
Dry pump
Inlet isolaon valve
Booster start delay BP start delay.. Range 1-200 seconds*
* Scroll through the opons by pressing the UP/DOWN keys. Press ENTER to accept the
new seng. Press CANCEL to exit back into the Booster pump start opons menu.
Press the UP/DOWN keys to select the new sengs and press ENTER to accept or
CANCEL to exit back to the Booster pump start opons menu.
9.4.9 MicroTIM opons menu
Scroll by pressing the UP/DOWN keys. Press ENTER to open a sub menu or CANCEL to
exit back to the Set sequences menu.
Table 37
MicroTIM opons menu
Opon Text on PDT line 2 Opons
on PDT line 2 aer pressing Enter
Set MicroTIM
Input 2
Input 2 ...
Select from:
Green Mode
Booster
Isolaon Valve
PID Enable
Second speed control
Set MicroTIM
Output 4
Output 4 ...
Select from:
Isolaon Valve
Warning
Booster
N
2
Flow
Water Flow
Exhaust Pressure
Control status
On Process State
Semicon Outputs
Use the UP/DOWN arrow to change and enter to select.
9.4.10 DP clean menu
Scroll by pressing the UP/DOWN keys. Press ENTER to open a sub menu or CANCEL to
exit back to the Set sequences menu.
Page 126
M58800880_H - Pump display terminal