Table 16
Water consumpon data (GXS750/2600/4200)
Ambient (°C)
Water Temperature (°C)
40 30 20
40
25 SLM
2 bar dP
20 SLM
1.3 bar dP
15 SLM
0.75 bar dP
30
20 SLM
1.3 bar dP
20 SLM
1.3 bar dP
15 SLM
0.75 bar dP
20
15 SLM
0.75 bar dP
15 SLM
0.75 bar dP
15 SLM
0.75 bar dP
2.7 DP clean high ow purge/solvent ush opon
Table 17
High ow purge/solvent ush data
Feature
Specicaon Rang
Pneumac valve gas
supply
Nitrogen or clean dry air
2.5 - 6.9 barg
(36 - 100 psig)
Pneumac valve inlet
connecon
3/8 inch compression ng
High ow purge gas
Air, nitrogen or other inert
gas which is compable with
process
Typically 170 slm (for the
GXS160 and GXS250 systems)
and 185 slm (for the GXS450
and GXS750 systems) at
atmospheric pressure at the
purge inlet connecon
High ow purge air lter
1/2 inch NPT male
(available as a spare, refer to
Spares on page 79)
DP clean solvent ush
uid inlet connecon
3/8 inch BSP male
DP clean solvent sucon
pipe connecon
3/8 inch BSP female
Notes:
1. The high ow purge/solvent ush kit is available as an opon.
2. The DP clean solvent sucon pipe is supplied with the pump but not ed.
2.8 External evacuaon system
The pumpdown performance on dry pumping systems ed with mechanical boosters
can be further enhanced by the use of an External Evacuaon System (EES) kit. The EES
kit will only provide performance improvement on pumpdown cycles lasng less than
30 seconds to pressures below 0.1 mbar. The EES kit must only be used on clean
applicaons.