Pump
Minimum ow rate required *
Minimum required pressure dierenal across
supply and return†
I/min bar
GXS250/2600 7 1
* All GXS dry pumping systems have a valve cooling system which will cause the coolant ow rate to
vary in response to pump load condions. Table: Water consumpon data (GXS160/250/1750/2600)
states that the "minimum ow rate required" under worst
‑
case pump load condions when all valves
are open. Flow rates need to be increased and/or coolant temperatures reduced if Glycol or other
coolants are used dependent on the diluon type.
† The dierenal pressure values given are the minimum dierenal pressures required across the
water supply/return at the point of connecon to the pump to achieve the desired ow when the
solenoid valves are open.
Table 13
Water consumpon data (GXS450 only)
Ambient (°C)
Water Temperature (°C)
40 30 20
40
15 SLM
1.8 bar dP
12 SLM
1.5 bar dP
10 SLM
1 bar dP
30
12 SLM
1.5 bar dP
12 SLM
1.5 bar dP
10 SLM
1 bar dP
20
10 SLM
1 bar dP
10 SLM
1 bar dP
10 SLM
1 bar dP
Table 14
Water consumpon data (GXS450/2600/4200)
Ambient (°C)
Water Temperature (°C)
40 30 20
40
19 SLM
2 bar dP
16 SLM
1.5 bar dP
12 SLM
1 bar dP
30
16 SLM
1.5 bar dP
16 SLM
1.5 bar dP
12 SLM
1 bar dP
20
12 SLM
1 bar dP
12 SLM
1 bar dP
12 SLM
1 bar dP
Table 15
Water consumpon data (GXS750 only)
Ambient (°C)
Water Temperature (°C)
40 30 20
40
19 SLM
2 bar dP
15 SLM
1.2 bar dP
12 SLM
1 bar dP
30
15 SLM
1.2 bar dP
15 SLM
1.2 bar dP
12 SLM
1 bar dP
20
12 SLM
1 bar dP
12 SLM
1 bar dP
12 SLM
1 bar dP