10.3.2 PDT alarms
If a PDT is ed, each alarm triggers an alarm message to be displayed. Refer to Event/
warning/alarm display and acknowledgement on page 121 for more informaon on how
alarms are handled by the PDT.
lists the alarm messages that might be displayed on the PDT with possible causes and
acons that should be taken.
Table 56
Alarms
Warning message on PDT Acon message on PDT
Alarm 1.01 - Stop Acvated on page 167 -
Alarm 1.01 - Sys Cong Fault on page 167 -
Alarm 39.12 - Exh Press High on page 168
Exhaust Blocked
Service Pump
Alarm 54.12 - MB Temp High on page 168 See manual
Alarm 55.12 / Alarm 63.12 - DP Temp High on
page 168
See manual
Alarm 174.10 - Booster Stopped on page 168 See manual
Alarm 176.01 - MB INV xxxx yyyy on page 168
xxxx yyyy
aaaaaaaaaaaaaaaa
Alarm 176.01 - MB Not Running on page 168 See manual
Alarm 176.13 - No MB Inv Comms on page 169 See manual
Alarm 184.10 - Dry Pump Stopped on page 169 See manual
Alarm 186.01 - DP INV xxxx yyyy on page 169
xxxx yyyy
aaaaaaaaaaaaaaaa
Alarm 186.01 - DP Not Running on page 169 See manual
Alarm 186.13 - No DP Inv Comms on page 169 See manual
Alarm 196.01 - DP Inv xxxx yyyy on page 169 Diag aaaa bbbb/zzzzzzzzzzzzzzz
Alarm 196.13 - No DP Inv Comms on page 169 See manual
Alarm 314.12 - Speed Too Low on page 169 Do not Restart/Contact Service
Fault
Alarm 1.01 - Stop Acvated
Cause The emergency stop has been acvated.
There is a fault with the EMS circuit or the EMS link plug has not been ed or
has become disconnected.
Remedy If the EMS buon has been used on the pump, refer to Restart the pump aer an
emergency stop or automac shut down on page 62 to reset it. Otherwise check
and reset the EMS circuit and restart the pump. The alarm message will remain on
the display unl the dry pumping system is restarted.
Fault
Alarm 1.01 - Sys Cong Fault
Cause The pump system type has not been set properly.
Page 167
M58800880_H - Fault nding