In Fast shut down mode, no gas purges are introduced and the pump stops quickly. This
method of shut down is not recommended.
In Auto shut down mode, a purge gas cycle is introduced and the pump shuts down
gradually over a me period. This is the recommended shut down mode and is the
default mode on the dry pumping system.
Smart Stop is an addional sequence that allows the user to dene the me period for
the gradual shut down and to congure a setpoint temperature. If Smart Stop is
enabled, the pump will perform a Smart Stop when the user selects Auto shut down.
Refer to Table: Stop sequences for the stop sequences.
Table 22
Stop sequences
Sequence Descripon
Stop with inlet purge
Inlet purge gas valve is opened (medium‑duty pumps only).
Inlet isolaon valve is closed (if ed).
Pump runs for 15 minutes before stopping.
All gas purge valves are closed before the pump stops.
Smart stop
Inlet purge gas valve opened (medium‑duty pumps only).
Inlet isolaon valve is closed (if ed).
Pump speed is ramped down over congurable shut down
me.
All purge gas valves are closed before pump stops.
Pump stops aer the congurable shut down me or aer a
congurable me period aer the pump temperature is below
a congurable setpoint.
The pump can be shut down using either the MCM MicroTIM, the PDT or the front panel
controls. Note that only the item in control can stop the pump. Refer to Priority of
control on page 11.
Note:
The EMS buon will always stop the pump. It does not maer which item has control.
Refer to Emergency stop on page 62.
If the pump is not going to be required for some me, switch o the electrical supply
and the cooling water supply. Seal the pump inlet and exhaust to prevent any moisture
in the atmosphere from corroding the pumping mechanism.
4.5.1 MicroTIM operaon
Use the control equipment to reset the pump start/stop signal to the interface
connector. The Running LEDs will then go o and the pump running status output signal
will open. An Auto shut down cycle is always performed when the pump is stopped
using the MCM MicroTIM.
4.5.2 PDT operaon
Press the stop buon on the PDT (refer to Pump display terminal on page 120 for more
informaon). Choose whether to select Auto or Fast shut down mode.
Page 60
M58800880_H - Operaon