Indicator
Name
LED
colour
Locaon Meaning
Green mode/
Standby
Green Front panel (item 10) Illuminates connuously when the
pump is in Green mode/standby
mode.
Flashes to indicate that the pump is
warming up. Refer to Determining
the pump status on page 57.
Warning Yellow Front panel (item 8)
Rear panel (item 6)
Illuminates connuously to indicate
a pump warning.
Flashes to indicate an internal
communicaon problem. Refer to
Pump controller communicaons on
page 173.
Alarm Red Front panel (item 9)
Rear panel (item 7)
Illuminates connuously to indicate
a pump alarm.
Flashes to indicate an internal
communicaon problem. Refer to
Pump controller communicaons on
page 173.
Ethernet LAN Green Rear panel (item 1) Flashes to indicate that there is a
network trac and Ethernet packets
are being received.
Ethernet Link Yellow Rear panel (item 2) Illuminates connuously to indicate
that the Ethernet protocol is acve.
4.2.1 Determining the pump status
It is not possible to fully determine the pump status by referring to only one status LED.
By looking at both the running LED and Green mode/standby LED together, the user can
work out the pump status. Refer to Table: Pump status.
Table 20
Pump status
Pump running LED Green mode/Standby LED Pump status
O O Pump stopped
Flashing Flashing Pump warming up
Flashing Illuminated connuously Pump is in Green mode/standby
mode
Illuminated
connuously
O Pump is on-process
Flashing O Pump is shung down
4.3 Green mode/standby mode
Green mode is used to reduce the power and purge gas consumpon of the pump when
o process. All dry pumping systems can support up to 9 dierent Green mode
conguraons. By default, only one green mode is enabled. To enable alternave Green
mode conguraons please contact our local service representave.
Page 57
M58800880_H - Operaon