2.2 Performance data
Table 3
Performance data
Pump
Characteriscs
Typical peak
pumping speed
Ulmate (sha seal
purge only)
Maximum connuous
inlet pressure
Units
m
3
/h
mbar mbar
GXS160 160
< 1 x 10
-2
1000
GXS160/1750 1160
< 1 x 10
-3
1000
GXS250 250
< 1 x 10
-2
1000
GXS250/2600 1900
< 1 x 10
-3
1000
GXS450 450
< 1 x 10
-2
1000*
GXS450/2600 2200
< 1 x 10
-3
1000*
GXS450/4200 3026
< 1 x 10
-3
1000*
GXS750 740
< 1 x 10
-2
1000*
GXS750/2600 2300
< 1 x 10
-3
1000*
GXS750/4200 3450
< 1 x 10
-3
1000*
* Speed may be limited.
2.3 Loading data
Refer to Installaon drawings on page 80 for the centre of gravity posions for dry
pumping systems. The loading data in Table: Loading data is for dry pumping systems
with an oponal levelling feet and castors. Refer to Figure: Levelling foot loads for foot
posions.
Table 4
Loading data
Pump
Load at levelling foot posion (kg)
1 2 3 4
GXS160 76 76 76 76
GXS160/1750 127 109 109 127
GXS250 76 76 76 76
GXS250/2600 154 103 103 154
GXS450 131 142 142 131
GXS450/2600 171 209 209 171
GXS450/4200 180 229 229 180
GXS750 160 180 180 160
GXS750/2600 215 244 244 215
GXS750/4200 229 259 259 229
Page 17