4. Switch on the electrical power to the dry pumping system. All the water valves in
the pump cooling system will automacally open for a period of around
10 seconds.
5. Adjust the water ow rate so that it meets the requirements given in Table: Water
consumpon data (GXS160/250/1750/2600). Note that the water valves will all
close again aer 10 seconds and the ow rate displayed by the water ow meter
will decrease (this is normal). If necessary, cycle the power to the pump to reopen
the valves for a further 10 seconds to connue seng the water ow rate.
6. Once the water ow rate has been set the water ow meter may be removed.
7.
Inspect the water hoses, pipelines and connecons and check that there are no
leaks.
Turn o the water supply while compleng the remainder of the installaon procedures.
3.10 Accessories
WARNING:
When ng accessories inside the enclosure, ensure that the pump is switched o.
Lockout and tagout the electrical supply before removing the enclosure panels.
WARNING:
The surfaces of the dry pump, booster and spools are very hot when the dry pumping
system is running. Allow these surfaces to cool to safe temperatures before installing
the accessories inside the enclosure. Be sure to route and secure accessory cables as
shown in their installaon manuals to prevent the cables from resng on hot
surfaces.
CAUTION:
The power to the dry pumping system must be switched o when the MCM
MicroTIM or acve accessory module is installed or removed. If it is not, these
modules may be damaged. Refer to the appropriate accessory manual for more
informaon.
CAUTION:
The relays ed in the MicroTIM are not suitable for switching inducve loads. If the
MicroTIM is connected to an inducve load (for example, a solenoid coil) then
suitable precauons should be taken. Fing a yback diode, of correct current and
voltage rang is recommended.
Refer to the individual accessories manuals for informaon about installaon.
Refer to How to set up the MCM MicroTIM using the PDT on page 156 for instrucons on
how to set up the MCM MicroTIM using the PDT.
Page 48
M58800880_H - Installaon

Table of Contents