restarted. If the alarm was caused by high pump temperatures, refer to Unplanned shut
down and alarms on page 61. Restart the dry pumping system as described in Start up
on page 54.
4.10 Dry pump clean
The high ow purge and the solvent ush kit is available as a factory‑t opon to clean
the pump mechanism on applicaons where large quanes of dust and scky deposits
are encountered. The cleaning process is run while the pump is in green mode/standby
mode and is carried out without the need to remove the pump enclosure. A PDT is
required to iniate the DP clean process. Refer to Table: DP clean sequence for details.
Table 25
DP clean sequence
Sequence Descripon
Dry pump clean
▪ Only operates when the pump is running in green mode/
standby mode.
▪ Purge gas or the solvent uid is admied into the pump for a
congurable me (default 20 minutes).
▪ Pump speed during the dry pump clean is congurable
(default 40 Hz).
▪
Gas purges may be congured to be on during the clean cycle
and/or for a period aer the DP clean valve has closed
(default o).
▪
Pump is not able to go on‑process unl the cycle has
completed.
▪ If dry pump clean is stopped by the user then the purge cycle
is completed.
▪ DP clean may be congured to start automacally when the
pump goes o process.
The DP clean high ow purge and solvent ush procedures can be run as oen as
required.
4.10.1 High ow purge
Use the following procedure to prepare for the high ow purge:
1.
Set up the dry pumping system ready for the high ow purge procedure as
described in High ow purge and solvent ush set up on page 51.
2.
Put the pump into green mode/standby mode. Refer to Green mode/standby mode
on page 57.
3.
Using the PDT, press the Setup buon to enter the setup menu and then select the
Command menu. An access code is needed to enter the Command menu. Enter
202 when prompted.
4.
Scroll down to the DP clean menu and then press ENTER to select.
5.
Select 'DP clean on' to start the high ow purge procedure.
The DP clean sequence will run automacally without requiring any operator
intervenon. Once the DP clean me has elapsed, the dry pumping system will return to
green mode/standby mode sengs. The pump can then be put back on‑process.
Page 63