14 Data Logger and Transmission of Data FLUXUS G60x
UMFLUXUS_G6V4-2EN, 2011-03-29 103
14.1.5 Deleting the Measured Values
14.1.6 Available Data Logger Memory
If the data logger is empty and a measurement is started with one physical quantity on
one measuring channel without storing the totalizer, approx. 100 000 measured values
can be stored. The available data logger memory can be displayed:
Max. 100 measuring data sets can be stored. The number of measuring data sets de-
pends on the total number of measured values stored in the previous measuring data
sets.
The time at which the data logger memory will be full can be displayed during the
measurement. All activated channels, totalizers and other values will be considered.
Select Special Funct.
\Delete Meas.Val. Press
ENTER.
Select yes or no. Press ENTER.
Select Special Funct.
\Instrum. Inform.. Press
ENTER.
The type and the serial number of the transmitter will be
displayed in the upper line.
The available data logger memory will be displayed in the
lower line (here: 18 327 additional measured values can
be stored). Press key BRK twice to return to the main me-
nu.
Scroll through the displays of the upper line with key
during measurement.
If the ringbuffer is activated and has overflown at least on-
ce, this display will be indicated.
Special Funct. ↕
Delete Meas.Val.
Special Funct. ↕
Instrum. Inform.
G60X-XXXXXXXX
Free: 18327
full= 26.01/07:39
54.5 m3/h
last= 26.01/07:39
54.5 m3/h