EasyManua.ls Logo

Fluke DSX-8000 - How to Do an Autotest Through a PoE Device

Fluke DSX-8000
700 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Versiv Series Cabling Certification Product Family
Technical Reference Handbook
124
PS NEXT (Power Sum Near End Crosstalk)
PS NEXT results show how much each wire pair is affected by the
combined crosstalk from the other pairs. PS NEXT is the difference
(in dB) between the test signal and the crosstalk from the other
pairs received at the same end of the cabling. The tester uses the
NEXT values to calculate PS NEXT. Higher PS NEXT values
correspond to better cabling performance.
PS NEXT results are typically a few dB lower (worse) than worst-
case NEXT results. Figure 53 shows the PS NEXT plot. The tester
puts the cursor at the worst margin.
Note
If the PS NEXT result is an an , the 4 dB rule applies.
See “About dB Rules” on page 150.
GPU105.PNG
Figure 53. PS NEXT Plot