Versiv Series Cabling Certification Product Family
Technical Reference Handbook
610
DSX-5000 Module: Tests and Frequencies Supported
Twisted Pair Cabling
TIA Cat 3, 4, 5, 5e, 6, 6A certification per TIA 568-C.2
ISO/IEC Class C and D, E, E
A
, F, F
A
certification per ISO/IEC
11801:2002 and amendments
Maximum frequency: 1000 MHz
Coaxial Cabling (optional DSX-CHA003 coaxial adapters required)
DS3, CATV, 10BASE-2, 10BASE-5, generic coaxial cable
Maximum frequency: 1200 MHz
DSX-5000 Standard Link Interface Adapters
DSX-CHA004 Class E
A
Channel Adapters
Jack type and life: shielded RJ45, 8-pin modular, >5000
insertions
Tests supported: shielded and unshielded cable, TIA Cat 3, 4,
5, 5e, 6, and 6A and ISO/IEC Class C, D, E, and E
A
channels
DSX-PLA004 Class E
A
Permanent Link Adapters
Plug type and life: shielded RJ45, 8-pin modular, >5000
insertions, on a 5 ft (1.5 m) cable
Tests supported: shielded and unshielded cable, TIA Cat 3, 4,
5, 5e, 6, and 6A, and ISO/IEC Class C, D, E, and E
A
permanent
links
DSX-5000 Long-Range Communication Mode
DSX-5000 modules have a long-range communication mode that
the module activates automatically when the cable is significantly
longer than 100 m. See “Long-Range Communication Mode
(DSX-5000)” on page 158.