Chapter 3: Certify Twisted Pair Cabling
Frequency-Domain Results
111
Continuous Tests
To do the wire map, length, or resistance test continuously, go to
the home screen, tap TOOLS > Single Tests, then tap a test.
The wire map test compares the cable connections to the outlet
configuration specified by the selected test limit and shows if
the connections agree or if they do not.
The length and resistance tests do not compare the results to a
test limit.
To save the result, tap SCAN OFF > SAVE. The saved test has an
for the overall result.
Frequency-Domain Results
Frequency-domain results are the measurements that change
with frequency, such as insertion loss and crosstalk. Figure 44
shows an example of results from a frequency-domain test.
How to Save Frequency-Domain Results as a Plot or a
Table
If Store Plot Data is on when you do a test, the saved results show
as plots. If Store Plot Data is Off, the tester does not save plot data
for frequency-domain tests or for the HDTDR/HDTDX analyzers.
You can see the plots before you save the test and exit the results
screen. Figures 44 and 45 show examples of the two types of
screens. Also see “Store Plot Data” on page 86.
Refer to Figure 44:
The location of the measurements. To switch between results
for the main and remote, tap REMOTE or MAIN (
).
Measured values for the wire pairs.
The limit line (in red) for the measurement.