Versiv Series Cabling Certification Product Family
Technical Reference Handbook
38
Step 1: See How Much Memory is Available
On the home screen, tap the TOOLS icon, then tap Memory
Status.
The MEMORY STATUS screen shows these values:
The percentage of memory available
The number of test records that are saved
The number of ID sets that have been downloaded to the
tester from LinkWare PC or LinkWare Live.
The memory space taken by other files, such as the databases
for projects and limits.
Step 2: Set Up a Twisted Pair Test
2-1 Attach DSX CableAnalyzer modules to the main tester and
the remote.
2-2 On the home screen, tap the test setup panel.
2-3 On the CHANGE TEST screen, tap NEW TEST.
2-4 On the TEST SETUP screen, tap each setting to make these
selections:
Module: This is the module you will use for the test. For a
test on twisted pair cable, tap DSX-8000 CableAnalyzer or
DSX-5000 CableAnalyzer.
Note
You can select settings for any module that the
tester can use. It is not necessary to install a
module before you set up a test for that module.
Cable Type: This is the type of cable you will test. The
CABLE TYPE screen shows the last 10 types of cable that
were selected. Tap the correct cable type.