DSX-8000 Module: Tests and Frequencies Supported
Twisted Pair Cabling
TIA Cat 3, 4, 5, 5e, 6, 6A, 8 certification per TIA 568-C.2
ISO/IEC Class C and D, E, E
A
, F, F
A
,Class I/II certification per ISO/
IEC 11801:2002 and amendments
Maximum frequency: 2000 MHz
Coaxial Cabling (optional DSX-CHA003 coaxial adapters required)
DS3, CATV, 10BASE-2, 10BASE-5, generic coaxial cable
Maximum frequency: 1200 MHz
DSX-8000 Standard Link Interface Adapters
DSX-CHA804 Cat 8/Class I Channel Adapters
Jack type and life: shielded RJ45, 8-pin modular, >5000
insertions
Tests supported: shielded and unshielded cable, TIA Cat 3, 4,
5, 5e, 6, 6A, 8 and ISO/IEC Class C, D, E, E
A
, Class I channels
DSX-PLA804 Cat 8/Class I Permanent Link Adapters
Plug type and life: shielded RJ45, 8-pin modular, >5000
insertions, on a 5 ft (1.5 m) cable
Tests supported: shielded and unshielded cable, TIA Cat 3, 4,
5, 5e, 6, 6A, 8 and ISO/IEC Class C, D, E, E
A
, Class I permanent
links