EasyManua.ls Logo

Fluke DSX-8000 - Certifiber Pro OLTS Loss;Length Specifications

Fluke DSX-8000
700 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Versiv Series Cabling Certification Product Family
Technical Reference Handbook
620
CertiFiber Pro OLTS Loss/Length Specifications
Specification
CertiFiber Pro
Multimode Modules
CertiFiber Pro
Singlemode Modules
Testing speeds
(excluding
referencing times)
Smart Remote mode (2 wavelengths, one direction): 3s
Far End Source mode
1
(2 wavelengths, one direction): 2s
Loopback mode (2 wavelengths, one direction): 2s
Input/output
connectors
Interchangeable connector adapter (LC standard on input,
SC standard on output)
Launch Condition
Encircled flux compliant to TIA 455-526-14-B,
ISO/IEC 14763-3, and IEC 61280-4-1
2,3
Fiber types tested
50/125 μm, 62.5/125 μm
multimode fiber
Singlemode fiber
Source type and
wavelengths
Multimode LED source
850 nm 30 nm
1300 nm 20 nm
Fabry-Perot laser diode
1310 nm 20 nm
1550 nm 30 nm
Maximum length
measurement
12 km 130 km
Length
measurement
accuracy
1.5 m plus 1 % of length
Output power
(nominal)
-24 dBm with EF-TRC -4 dBm
Output power
stability
4
0.05 dB over 8 hours
0.03 dB over 15 minutes
0.1 dB over 8 hours
0.08 dB over 15 minutes
1. In Auto CertiFiber Pro mode. In Auto SimpliFiber Pro mode: < 4 seconds (2
wavelengths). With the source in continuous-wave mode: < 1 second (1 wavelength).
2. At the output of the EF-TRC.
3. Variations between EF measurement equipment may occur but EF compliance can be
expected with a 95 % confidence factor.
4. At constant temperature, relative to power level after 15 minute warm up.