Chapter 21: Specifications
Power
603
Power
DSX-8000 CableAnalyzer Module Specifications
Note
Specifications for tests on twisted pair cabling
apply to 100
cable. For information on
measurement performance for cable with a
different impedance, contact Fluke Networks.
DSX-8000 Times for a Full, 2-Way Autotest
Battery type Lithium ion battery pack, 7.2 V
Charging Temperature +32 °F to +113 °F (0 °C to +45 °C)
Battery life 8 hr typical
Charge time Tester off: 4 hours to charge from 10 % capacity to
90 % capacity.
Tester on: 6 hours to charge from 10 % capacity to
90 % capacity with the tester on.
Power Adapter Input: 100 to 240 VAC ±10%, 50/60Hz
Output: 15 VDC, 2 A maximum
Class II
Category Autotest Time
1,2
Cat 6A/Class E
A
8 seconds
ISO 11801 PL Class E (includes TCL)
< 16 seconds
3
Cat 8/Class I/II < 16 seconds
Cat 8/Class I/II, All tests < 34 seconds
1. On unshielded cable. Autotests on shielded cable take approximately 1.5 seconds
longer.
2. The first Autotest after power-on takes approximately 2 seconds longer. If the
Autotest includes common-mode measurements, add 0.8 seconds more.
3. Also applicable to any Cat 6/Class E Autotest with common-mode measurements.

Table of Contents