Chapter 21: Specifications
Visual Fault Locator
629
OptiFiber Pro HDR DataCenter OTDR Specifications
Visual Fault Locator
Pulse Widths
(nominal)
3 ns to 30 ns
Maximum Range 5 km (16,404 ft)
Averaging Time Automatically set to Best Resolution
Target Test Times
1310 nm and 1550 nm:
20 seconds
Maximum Test
Times
1310 nm and 1550 nm:
40 seconds
End Threshold 3.5 dB
On/off control Mechanical switch and a button on the
touchscreen
Output power
(into SM fiber with SC/UPC
connector)
316 μw (-5 dBm) peak power 1.0 mW
(< 0 dBm)
Operating wavelength 650 nm nominal
Spectral width (RMS)
3 nm
Output modes Continuous wave and pulse mode (2 Hz to 3 Hz)
Connector adapter 2.5 mm universal
Laser safety Class II CDRH over operating temperature range
Complies to EN 60825-2