605
DSX-8000 Measurement Accuracy
For Category 8/Class I/II tests, the DSX-8000 CableAnalyzer
modules are compliant with Level 2G requirements of TIA 1152A.
For Class I/II tests, the DSX-8000 CableAnalyzer modules are
compliant with Level VI requirements of IEC 61935-1.
For Category 6A/Class E
A
tests, the DSX Series CableAnalyzer
modules are compliant with Level IIIe requirements of TIA 1152
and Level IV of IEC 61935-1.
Worst case accuracy performance parameters are used for asterisk
(*) results reporting. These are based on computation of the
overall measurement accuracy based on the worst case of each
parameter at each frequency data point. Observed differences
between laboratory equipment and DSX CableAnalyzer modules
using calibration verification artifacts were used as a
confirmation.
The next table shows the accuracy performance parameters for
the DSX-8000 modules.
DSX-8000 Level 2G Accuracy Performance Parameters
per IEC Guidelines
Parameter Baseline Field Tester Field Tester with
Level 2G
Permanent Link
Adapter
Field Tester with
Level 2G Channel
Adapter
Dynamic
range
3 dB over test limit
NEXT and FEXT 65 dB
PS NEXT and FEXT 62 dB
Amplitude
resolution
0.1 dB
-continued-