EasyManua.ls Logo

Fluke DSX-8000 - Delay Skew; DC Loop Resistance; DC Resistance Unbalance; HDTDX Analyzer Specifications for Cables <100 M (328 Ft)

Fluke DSX-8000
700 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Versiv Series Cabling Certification Product Family
Technical Reference Handbook
616
Delay Skew
DC Loop Resistance
DC Resistance Unbalance
HDTDX Analyzer Specifications for Cables <100 m (328 ft)
Parameter Twisted Pair Cabling
Range 0 ns to 100 ns
Resolution 1 ns
Accuracy 10 ns
Parameter DSX-5000 DSX-8000
Range 0 to 540 0 to 540
Resolution
0.1 0.01
Accuracy
(1 + 1 %) (0.5 + 1 %)
Overload
Recovery Time
Less than 10 minutes to rated accuracy following an
overvoltage. Referencing is required after repeated or
prolonged overvoltage.
Parameter Twisted Pair Cabling
Resolution 0.005
Accuracy for unbalance
within a pair
± (0.025 + 0.3% of loop resistance)
Accuracy for unbalance
between pairs
±(0.025 + 0.3% of mean loop resistance for the
two pairs)
Parameter Twisted Pair Cabling
Distance accuracy (0.3 m (1 ft) + 2 % distance)
Distance resolution 0.1 m or 1 ft

Table of Contents