EasyManua.ls Logo

Fluke DSX-8000 - Optifiber Pro OTDR Module Specifications

Fluke DSX-8000
700 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Versiv Series Cabling Certification Product Family
Technical Reference Handbook
622
OptiFiber Pro OTDR Module Specifications
Multimode Singlemode
OTDR Port SC standard
Cleanable and
interchangeable
UPC polish
SC standard
Cleanable and
interchangeable
UPC polish
Wavelengths 850 nm 10 nm
1300 nm +35 / -15 nm
1310 nm 25 nm
1550 nm 30 nm
Compatible Fiber Types 50/125 μm
62.5/125 μm
multimode fiber
Singlemode fiber
Event Dead Zone
1
850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
Attenuation Dead Zone
2
850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
1. Measured at 1.5 dB below non-saturating reflection peak with the shortest pulse
width. Reflection peak < -40 dB for multimode and < -50 dB for singlemode.
2. Measured at 0.5 dB deviation from backscatter, with a reflection peak < -40 dB and
a 3 ns pulse width for multimode, and < -50 dB and a 10 ns pulse width for
singlemode.