Chapter 17: Use Projects
Tutorial: How to Use a Project for Tests with OptiFiber Pro and CertiFiber Pro
539
Step 6: Add Results from a Loss/Length Test
Select the loss/length test to do next on fibers 1A and 1B.
6-1 On the home screen, tap the test setup panel.
6-2. On the CHANGE TEST screen (Figure 201), tap the Smart
Remote test, then tap USE SELECTED.
6-3. Attach CertiFiber Pro modules to the main and remote
testers.
6-4. On the home screen, the Next ID panel shows the first two
IDs, 1A and 1B, that do not contain loss/length results. To see
how the tester uses the IDs for the fibers connected to its
INPUT and OUTPUT ports, tap the panel.
6-5. Clean and inspect the connectors on the tester, remote, and
test reference cords.
6-6. To set the reference for the fiber test and make sure your
test reference cords are good, tap SET REF, tap RUN
WIZARD, then do the steps given by the wizard.
Note
When you make connections to the fiber link,
make sure you connect fiber 1A to the main
tester’s INPUT port and fiber 1B to the main
tester’s OUTPUT port.
6-7. When you have completed the reference and TRC
verification procedures and connected the testers to the
fiber link, tap TEST or press .
When the test is completed and if it passed, the tester
automatically saves the results for the Smart Remote test
with the OTDR results in IDs 1A and 1B. Figure 204 on page
540 shows the RESULTS screen for the tests completed for
this project.