Versiv Series Cabling Certification Product Family
Technical Reference Handbook
86
Store Plot Data Off : The tester does not save plot data for
frequency-domain tests or for the HDTDR/HDTDX
analyzers. You can see the plots before you save the test
and exit the results screen. The saved results show
frequency-domain measurements in a table and do not
include the HDTDR/HDTDX plots.
On : The tester saves plot data for all frequency-
domain tests required by the selected test limit and for
the HDTDR/HDTDX analyzers.
HDTDR/HDTDX Fail/Pass* only: The tester shows HDTDR and HDTDX
analyzer results only for Autotests with PASS*, FAIL*, or
FAIL results.
All Autotests: The tester shows HDTDR and HDTDX
analyzer results for all Autotests.
Never: The tester never shows HDTDR or HDTDX analyzer
results. This setting also disables the automatic
diagnostics, so the FAULT INFO screens never show.
To get HDTDR/HDTDX analyzer results you can also tap
Tools > Diagnostics.
For more information about the HDTDR and HDTDX
analyzers, see Chapter 6.
Bi-directional This setting shows only when you select a patch cord test
limit. It is used mainly by patch cord manufacturers to
make the Autotest time shorter.
On: The tester does tests in both directions.
Off: The tester does tests in only one direction, which
decreases the Autotest time.