Chapter 3: Certify Twisted Pair Cabling
Frequency-Domain Results
145
Newer Connectors Reduce Mode Conversion
Newer Cat 6A connector designs compensate for the inherent
unbalance of RJ45 connectors, and have much lower mode
conversion than older designs. Links constructed with these
connectors have better EMI rejection and also tend to have better
alien crosstalk performance.
GPU93.EPS
Figure 65. Common-Mode Voltage Converts to
Differential-Mode Voltage in an RJ45 Connector
8
7
6
5
4
3
2
1
Pair
4
Pair
3
Pair
2
Pair
1
The common-mode voltage on wire 8
induces voltage on wire 6, but not wire 3,
so pair 3 develops a differential voltage.