Versiv Series Cabling Certification Product Family
Technical Reference Handbook
284
Notes
The SET REFERENCE screen shows reference
connections for the selected reference method.
Figure 120 shows connections for the 1 Jumper
reference.
When you set the reference, keep the fiber as
straight as possible.
1-8 Turn on the optical source. On the CertiFiber Pro remote
module, hold down the button adjacent to the VFL port for 3
seconds to turn on the multimode source. See Figure 121.
On CFP-QUAD modules, to turn on the singlemode source,
press the button again.
Note
The CertiFiber Pro module in the remote always
operates in auto wavelength mode. The output
port transmits both wavelengths (850 nm and
1300 nm or 1310 nm and 1550 nm). The signal
includes identifiers that tell the main tester when
to measure power at each wavelength.
1-9 To enter the length of the test reference cord you will add to
connect to the fiber under test, tap TRC LENGTH on the SET
REFERENCE screen. The length you enter does not change the
test results. The tester saves the length with the results to meet
TIA reporting requirements.
1-10 Tap SET REFERENCE.
If reference values are unacceptable, you can use the
FiberInspector probe to inspect connectors. To turn on the
probe, press the button on the probe. To go back to the
reference screen, tap .
1-11 If you did not use the connection wizard, go to step 3.