Versiv Series Cabling Certification Product Family
Technical Reference Handbook
342
GPU22.EPS
Figure 143. EventMap Example 2
Length of the tail cord (top) and launch cord (bottom).
A non-reflective loss event:
: An APC connector or a splice. Measurements for the event
are all within the test limits. If the event has negative loss, it is a
Gainer. See page 351.
If Macrobend Detection is Off, this could be a bend. If the event
is a bend, and Macrobend Detection is On, the EventMap shows
the bend icon. Macrobend detection is available only for
singlemode fibers.
: One or more measurements for the event exceeds the limit.